3516C (HD) CI/D2 Hazardous Location

3516C (HD) CI/D2 Hazardous Location

Cat 3500 offshore generator sets are specifically designed for drilling and production operations offshore. Decades of experience powering offshore vessels and platforms make have evolved into a product that offers proven performance, low emissions, high durability, and low owning and operating costs. Cat generator sets are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty. Cat 3516C (HD) Class I/ Division 2 offshore generator set ratings: 1285-1530 ekW @ 60 Hz (1200 rpm) and 2250 ekW @ 60 Hz (1800 rpm).

Engine Specifications

Minimum Rating

2625kV·A

Maximum Rating

2625kV·A

Emissions

EPA Tier 2, IMO Tier II

Engine Control

ADEM A4

Bore

6.7in

Weight

38581lb

Displacement

4764in³

Fuel System

EUI

Stroke

8.5in

Aspiration

Dual Turbocharged-Aftercooled

Dimensions

Length

264in

Height

99.8in

Width

78.2in

Capacity for Liquids

Lube Oil System - Refill

107gal (US)

Cooling System - Engine

62gal (US)

Standard Equipment:

  • Air Inlet System
    • Aftercooler core, corrosion resistant (air side)
    • Air cleaner, regular duty with service indicators
    • Dual turbochargers, rear mounted
  • Control System
    • Dual Caterpillar A4 electronic engine control with electronic unit injector fuel system and rigid wiring harness.
    • 24 VDC (less than 10A) to be provided by customer at Power Distribution Panel to power engine electrical system.
  • Cooling System
    • Jacket water (JW) engine cooling and two-stage jacket water/separate circuit (SCAC) charge air cooling
    • To ensure compliance in use, radiators or heat exchangers must be capable of rejecting sufficient heat to allow proper engine operation at worst site conditions.
    • The radiator or heat exchanger must supply 48C (118 F)
    • SCAC cooling water to the aftercooler inlet of at least 200 gal/min at ambient temperature of 30C and at site conditions (including altitude considerations)
  • Exhaust System
    • Dry gas-tight exhaust manifolds with heat shields, dual turbochargers with water-cooled bearings and heat shields.
    • Exhaust outlet: 305 mm (12 in) round flanged outlet, vertical orientation
  • Flywheels & Flywheel Housings
    • Flywheel, SAE No. 00, 183 teeth Flywheel housing, SAE No. 00
    • Flywheel housing, SAE No. 00
    • SAE standard rotation
  • Fuel System
    • Duplex Fuel filter, LH service. Simplex fuel filter, RH service
    • Fuel transfer pump
    • Fuel priming pump, RH
    • Electronically Controlled Unit Injectors
    • Customer connection located at lower right front of engine
    • SOLAS shielding
  • Instrumentation
    • Engine mounted instrument panel with four position switch, over speed shutdown notification light, emergency stop notification light, graphical display unit for analog or digital display of: oil and fuel pressure, oil and fuel filter differential, system DC voltage, exhaust and water temperature, air inlet restriction, service meter, engine speed, fuel consumption (total and instantaneous)
  • Lube System
    • Top mounted crankcase breather, RH oil filter, RH oil filler, gear type oil pump, deep sump oil pan, recommended use of Caterpillar Diesel Engine Oil 10W30 or 15W40
  • Mounting System
    • Mounting rails and isolation system based on customer request
  • Electrical System
    • MCS certified Class I / Divison 2
    • Low Smoke Zero Halogen Wiring Harness
  • Protection System
    • A-III Electronic Monitoring System provides customer programmable engine de-ration strategies to protect against adverse operating conditions
    • Emergency stop push button (located in Electronic Instrument Panel) Safety shutoff protection for oil pressure and water temperature, over speed protection
  • Hazardous Location
    • Only electrical system is hazardous environment certified
    • NEC 500 Class I Division 2 for gas groups C and D
    • Temperature class is T3 for ambient temperatures from -10 C to 50 C
    • Class I/ Division 2 CMPD
  • Generator And Generator Attachments
    • Class I / Division 2 designed to customer's specifications
    • Insulation for harsh environment protection

Optional Equipment:

Contact Us

Get A Quote

Thank you for your interest in Mustang Cat. We are here to help you in any way that we can. If you have a question, need equipment advice or just need additional information, we want to hear from you. You can email, phone or fill out the form below and we will be happy to connect with you.

    true I agree to all the terms and conditions

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.