3412C | 900 kVA 50Hz Generator Set
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating
Minimum Rating
Emissions/Fuel Strategy
Voltage
Frequency
Speed
Duty Cycle
Engine Specifications
Engine Model
Bore
Stroke
Displacement
Compression Ratio
Aspiration
Fuel System
Governor Type
Generator Set Dimensions
Length - Maximum
Width - Minimum
Width - Maximum
Height - Maximum
Dry Weight - Genset (minimum)
Dry Weight - Genset (maximum)
Standard Equipment:
-
- Air Inlet System
-
- Air cleaner, single element canister type with service indicator
-
- Control Panel
-
- GCCP Control panel
- Emergency stop pushbutton
- Overspeed
- Text alarm/event descriptions
- Low coolant temperature
- Frequency (Hz)
- Overcurrent (50 / 51)
- 4 programmable relay outputs (Form A)
- Volts (L-L & L-N)
- Programmable protective relaying functions:
- Warning/shutdownn with common LED indication of shutdowns for:
- 24 Volt DC operation
- Over/under voltage (27 / 59)
- Engine cycle crank
- Over/under frequency (81 o/u)
- Remote CAN annunciator
- Remote Serial annunciator
- kW (per phase, average & percent)
- Digital I/O module
- Failure to start (overcrank)
- Low oil pressure
- Low coolant level
- Run/auto/ stop/control
- 6 programmable digital inputs
- Accessory module data link
- Features include:
- Compatible with the following optional modules:
- Serial annunciator module data link
- kVA (per phase, average & percent)
- Voltage adjust
- RPM
- Generator temperature monitoring module
- kVAr (per phase, average & percent)
- 2 Programmable relay outputs (Form C)
- DC volts
- Communications
- Local annunciator
- Power factor (per phase & average)
- Speed adjust
- Emergency stop
- Reverse power (kW) (32)
- coolant temperature
- Digital indication for:
- Reverse reactive power (kVAr) (32RV)
- Customer data link (Modbus RTU)
- kW-hr (total)
- Amps (per phase & average)
- High coolant temperature
- Generator phase sequence
- Oil pressure (psi, kPa or bar)
- Operating hours
- 2 Programmable digital outputs
- Environmental sealed front face
-
- Cooling System
-
- Fan and belt guards
- Radiator with guard (Sized for 50 degrees C)
- Coolant drain line with valve, piped to edge of base
- Coolant level shutdown
- Caterpillar extended life coolant
-
- Exhaust System
-
- Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
-
- Fuel System
-
- Primary and Secondary fuel filters
- Water seperator
- Flexible fuel lines terminated on base
- Fuel priming pump
-
- Generator And Attachments
-
- 3-phase sensing
- Busbar termination
- SR4B self excited
- 2:1 Volts/Hz
- Class F temperature rise
- 12 Leads
- Class H insulation
- Reactive droop
- VR6 voltage regulator
-
- Governing System
-
- Cat electronic governor
-
- Lube System
-
- Oil drain line with valve, piped to edge of base
- Oil filter
- Fumes disposal, piped to front of radiator
- Lubricating oil
-
- Mounting System
-
- Base, formed steel with linear vibration isolators between base and engine-generator
-
- Starting / Charging System
-
- Fuel shutoff solenoid
- 45 amp Charging alternator
- Battery with rack, cables
- 24 volt starting motor
Optional Equipment:
-
- Air Inlet System
-
- Dual element air cleaners
- Heavy duty air cleaners
- Open element air cleaners
-
- Circuit Breakers
-
- 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
- 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
-
- Control Panel
-
- Ground fault relay
- Vandal proof panel door
- First local annunicators
- Common alarm/shutdown relay
- Remote custom annunicator
- GCCP Control panel
- Generator running VFC
- GCCP Control panel
- Local discrete I/O package
- Generator temperature monitoring package
-
- Cooling System
-
- Radiator duct flange
- Jacket water heaters
-
- European Certifications
-
- Eurasian Conformity (EAC) mark
-
- Exhaust System
-
- Manifold and turbocharger guards
- Through wall installation kit
- Elbow kit
- Mufflers
-
- Generator And Attachments
-
- Permanent magnet excitation (PMG)
- Space heater
- Digital voltage regulator
- Oversize and premium generators
-
- Lube System
-
- Manual sump pump
-
- Mounting System
-
- Fuel tank base (1200 ltr)
-
- Special Tests / Reports
-
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
-
- Starting / Charging
-
- Battery disconnect switch
- Heavy duty starting system
- Battery chargers
- Oversize batteries
-
- Governing System
-
- Electronic load share
Contact Us
Get A Quote
Thank you for your interest in Mustang Cat. We are here to help you in any way that we can. If you have a question, need equipment advice or just need additional information, we want to hear from you. You can email, phone or fill out the form below and we will be happy to connect with you.